Here are a condensed list of the Product Features:
Applications:
• Used for L-shaped rooms, long narrow rooms, or where one point source will not properly circulate air throughout the room
• For cellars that will store or mature wine for long periods of time
• Located outside the cellar, the supply and return air is ducted into the room similar to a central air conditioner
• No visible mechanical equipment in cellar
• Ducted units need only supply registers and return air grilles in the cellar leaving more wall space for racking and art work
• Ducting can be placed in soffits if room construction is already complete
• The most quiet style of all refrigeration systems
• Humidification, and dehumidification air handler systems allow for total climate control in the wine cellar
• Accurate, fast acting thermostat controls the refrigeration system and all accessories
• Can be used with either an indoor or outdoor remote condensing unit, moving heat and noise away from the cellar
• Wooden and decorative metal registers available
• Must be installed and adjusted by a qualified HVAC technician
Air Handler WZAH4800a:
• ETLC listed air handler in accordance with UL1995
• Phenolic coated, aluminum fin-copper tube evaporator coil
• Factory balanced, forward curve direct drive blower, with 115V, 3 speed, PSC motor
• Cabinet with fully insulated 3/4" fiberglass with an R value of 3.26
• 1" disposable filters standard on all units
• Vertical units have duct connections on return air inlet and a large blower access panel in front
• Horizontal units have 3/8" NC thread nuts in each corner of top panel for easy suspension and are designed for top or bottom blower access
Specifications & Assembly Manuals :
4800a BTUH Air Handler Specifications
Condenser:
Voltage | HP | Ampacity Max. | Fuse Min. | Wire Size | RLA/LRA | dB |
230/208-60-1 | 8.6 | 15 | 12-2 w/Gr | 6.4/31.0 | 53 |
Vertical Air Handler:
Voltage | HP | Ampacity Max. | Fuse Min. | Wire Size | dB |
115-60-1 3spd. | 1/10 | 1.2 | 15 | 14-2 w/Gr | 56 |
Thermostat:
Humidifier:
Dehumidification:
Approximate Shipping Weight:
Crate Size:
Here are a condensed list of the Product Features:
Applications:
• Used for L-shaped rooms, long narrow rooms, or where one point source will not properly circulate air throughout the room
• For cellars that will store or mature wine for long periods of time
• Located outside the cellar, the supply and return air is ducted into the room similar to a central air conditioner
• No visible mechanical equipment in cellar
• Ducted units need only supply registers and return air grilles in the cellar leaving more wall space for racking and art work
• Ducting can be placed in soffits if room construction is already complete
• The most quiet style of all refrigeration systems
• Humidification, and dehumidification air handler systems allow for total climate control in the wine cellar
• Accurate, fast acting thermostat controls the refrigeration system and all accessories
• Can be used with either an indoor or outdoor remote condensing unit, moving heat and noise away from the cellar
• Wooden and decorative metal registers available
• Must be installed and adjusted by a qualified HVAC technician
Air Handler WZAH4800a:
• ETLC listed air handler in accordance with UL1995
• Phenolic coated, aluminum fin-copper tube evaporator coil
• Factory balanced, forward curve direct drive blower, with 115V, 3 speed, PSC motor
• Cabinet with fully insulated 3/4" fiberglass with an R value of 3.26
• 1" disposable filters standard on all units
• Vertical units have duct connections on return air inlet and a large blower access panel in front
• Horizontal units have 3/8" NC thread nuts in each corner of top panel for easy suspension and are designed for top or bottom blower access
Specifications & Assembly Manuals :
4800a BTUH Air Handler Specifications
Condenser:
Voltage | HP | Ampacity Max. | Fuse Min. | Wire Size | RLA/LRA | dB |
230/208-60-1 | 8.6 | 15 | 12-2 w/Gr | 6.4/31.0 | 53 |
Vertical Air Handler:
Voltage | HP | Ampacity Max. | Fuse Min. | Wire Size | dB |
115-60-1 3spd. | 1/10 | 1.2 | 15 | 14-2 w/Gr | 56 |
Thermostat:
Humidifier:
Dehumidification:
Approximate Shipping Weight: